DLM Dual Tech Corner Mount Sensor
LMDX-100
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The LMDX-100 Digital Dual Technology Corner Mount Occupancy Sensor uses both passive infrared (PIR) and ultrasonic technologies to achieve precise occupancy sensing for energy-efficient.
BAA
No
- No
- Yes
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Plug n’ Go™ automatic configuration for quick installation and maximum energy savings
- Push n’ Learn™ functionality for customization without the need for tools or a PC
- Digital Lighting Management components plug together on a free-topology Category 5e DLM local network
- Infrared (IR) transceiver for wireless configuration and control
- Ultrasonic diffusion technology spreads coverage to a wider area (patented); 40KHz signal
- Detection Signature Processing eliminates false triggers and provides immunity to RFI and EMI
- Sensor coverage tested to NEMA Guide Publication WD 7-2000
Specifications
General Info
Product Line | Wattstopper | ||
Color | White | ||
UPC Number | 754182926282 | ||
Country Of Origin | China | ||
Product Series | LMDX-100 | ||
Features | Adjustable Time Delay, Indicator Lights, Room Controller Required, Sensitivity Adjustment | ||
Installation Location | Ceiling, Corner, Wall | ||
Included | Mounting Plate, RJ-45 Coupler | ||
Standard | UL, cUL, FCC part 15, RoHS, PEP | ||
Warranty Type | 5-Year | ||
Type | Sensor |
Dimensions
Product Width US | 2.5 in | ||
Product Weight US | 0.3 lb | ||
Product Volume US | 114.0 cu in | ||
Product Depth US | 3.8 in | ||
Product Height US | 3.0 in |
Additional Information
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. | |
DesignLights Consortium Qualified System | Yes | ||
Security | Yes | This product is ioXt certified |
Technical Information
Operating Temperature Min | 32 °F | ||
Ultrasonic Frequency | 40 kHz | ||
Has Battery | No | ||
Number of Connections | 1 | ||
Sensor Type | Occupancy | ||
Operating Temperature Max | 131 °F | ||
Sensor Mounting Height | 10 ft | ||
Sensor Technology | Dual Technology, Passive Infrared (PIR), Ultrasonic | ||
Topology | Free Topology | ||
Input Voltage | 24 VDC | ||
Indoor/Outdoor | Indoor | ||
Sensor Coverage | 2000 sq ft | ||
Mounting Type | Ceiling Tile, J-Box, Surface | ||
On Function | Auto On | ||
Current Draw | 20 mA | ||
Operating Temperature | 0°-55°C, 32°-131°F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Sensing Range | 28 ft, 45 ft | ||
Wire Connection Type | RJ-45 | ||
Storage Temperature | 23° - 176° F, -5° - 80° C |
Resources
Installation Instructions
CAD Drawings
90-411 - LMDX-100 Dimension and Mounting
png
90-411 - LMDX-100 Dimension and Mounting
dxf
90-411 - LMDX-100 Dimension and Mounting
dwg
LMDX-100 Symbol
png
LMDX-100 Symbol
dxf
LMDX-100 Symbol
dwg
LMDX-100cp - LMDX-100 Coverage Pattern
dxf
LMDX-100cp - LMDX-100 Coverage Pattern
png
LMDX-100cp - LMDX-100 Coverage Pattern
dwg
View More
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
I have a lmdx-100 and both red and blue leds are flashing and the loads stay on, I think it may be in pnl mode if so how do I exit.
Please refer to the instruction sheet available for download on the product page for button push sequences to bind the sensor to a load or reach out to tech support for more assistance.
Legrand Technical Support:
Phone: 1 800-879-8585, Option 3 then Option 1
Mon - Fri: 7am - 7pm CST (excluding holidays)
Date published: 2023-05-18
I am an electrical contractor, was looking for a document or something. Just wanted to confirm if i could add two LMDX100 to one room controller. Also which room controller i could use with LMDX100 . THank you
Good morning
The LMDX-100 wall mount sensor was design to work with any DLM controller. If you are trying to control one room or load, it can be connected to an LMRC 101, 111, or 211. If you are using 2 loads there's the LMRC 102, 112, and 222. If you are using 3 loads there's the LMRC 213. With all that being said it will work with any one of the LMRC control module. Also you can add more then one or more LMDX to any of your controllers.
Date published: 2022-09-15
Bazaarvoice SAP Hybris Integration Version 2.8.1