10-Way RJ45 Telephone Module with RJ31X
TM1045
On-Q
Bazaarvoice SAP Hybris Integration Version 2.8.1
$59.99 USD
This telephone module distributes up to 4 incoming telephone lines (RJ45) to 10 locations.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | On-Q | ||
UPC Number | 804428066910 | ||
Country Of Origin | China | ||
Application Sector | Residential |
Additional Information
Product Environmental Profile | Yes |
Listing Agencies / 3rd Party Agencies
cULus Listed | Yes |
Technical Information
Number of Ports | 12 | ||
Connection | plated Gold over Nickel, Phosphor Bronze contacts |
Resources
Cutsheet
Installation Instructions
CAD Drawings
Guide Form Specifications
Product Environmental Profile
Customer CAD PDF
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Can you confirm the wiring standards for the house phone wiring? i.e. If we have CAT5e/6 wiring in the walls for use with phone/voice lines, what is the pin-out between the male ends plugging into this module vs. the female ends in the wall jacks?
This unit conforms to the 568A standard
This means that pins 4 and 5 are line 1, pins 3 and 6 are line 2, pins 1 and 2 are Line 3 and pins 7 and 8 are Line 4.
Date published: 2023-06-21
Can this be used as an extender? In other words, my home currently already has a telecom module. After an addition to the home, I now need to add a few other lines. Is it possible to utilize this product to extend the existing telecom module I have?
you would connect the last out of the existing unit to the first out of the new unit.
connecting to the service in of the TM1045 would have a RJ31X line seizure between the old and new units. Connecting to the first output bypasses that line seizure mechanism.
Date published: 2022-08-01
I believe my unit is malfunctioning. How can I troubleshoot it?
Disconnect all cables from the device.
Test your incoming phone cable with a wired telephone test set. Assuming you get dialtone:
Connect your telephone input cable to the input port.
Connect a wired handset to one of the output ports.
If you do not get dialtone, the module is faulty.
You can bypass the RJ31x line seizure port by connecting your incoming telephone feed to one of the output ports and connecting your telephone test set to one of the other output ports.
This could be considered a valid workaround if the unit is out of warranty and you don't wish to replace it.
Date published: 2021-07-28
can this work with Vonage or other voip devices? While connecting the line to service in in TM1045, the phone line goes dead. Is there a specific way to handle this ?
that would indicate a Line Seizure port failure. Replace the TM1045, OR, just connect the Vonage to one of the output ports, which will activate the other inside phone jacks bypassing the Security Line Seizure port.
Date published: 2022-10-20
how do you remove a Legrand Telephone Module (TM1045) from the metal box where it is mounted? I have removed the actual plug module, but cannot remove the base.
The base has two plunger pins similar to the 4 on the TM1045 module itself. They are located on the right side of that bracket. Pull them out then the bracket tilts up from the side where you pulled the pins out.
Date published: 2021-03-01
Can the TM 1045 telephone module be used as a web smart network switching station?
No, it distributes analog phone service only.