The LMIN-104 Input Interface allows integration with third party devices to provide additional functionality in a Digital Lighting Management (DLM) system.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Input interface for integration of third party devices
- Component of Digital Lighting Management integrated control systems
- Fits into standard single gang wallbox; optional DIN rail mounting
- Hinged dust cover protecting two RJ45 ports
- Status LED for each input
- Four isolated 2 wire contact closure inputs for up to two control devices
Specifications
General Info
Color | White | ||
Product Series | LMIN | ||
Type | Interface | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | China | ||
Installation Location | Ceiling | ||
Warranty Type | 5-Year | ||
Standard | UL 2043, cUL, RoHS | ||
UPC Number | 754182940868 | ||
Works With | Third Party Devices |
Dimensions
Product Depth US | 6.0 in | ||
Product Height US | 4.0 in | ||
Product Volume US | 192.0 cu in | ||
Product Width US | 8.0 in | ||
Product Weight US | 2.0 lb |
Additional Information
RoHS Compliant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. |
Technical Information
Current Draw | 20 mA | ||
Number of Connections | 3 | ||
Connector Type | RJ-45, Terminal Block | ||
Contact Configuration | 2-wire Momentary, 3rd Party BAS, 3-wire Momentary, Maintained Switch, Occupancy Sensor, Photocell Sensor | ||
Contact Rating | 24 VDC | ||
Indoor/Outdoor | Indoor | ||
Input Voltage | 24 VDC | ||
Mounting Type | 3 in Octagonal Box, 4 in J-Box, DIN Rail, Inside 2-Gang J-Box, Screw Holes | ||
Number of Relays | 2 | ||
Operating Temperature | 0°-40°C, 32°-104°F | ||
Operating Temperature Max | 104 °F | ||
Operating Temperature Min | 32 °F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Storage Temperature | 23° - 176° F |
Resources
Installation Instructions
CAD Drawings
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Does LMIN-104 device have the capability to interface the lighting control devices (such as room controller, occupancy sensor) with the Fire alarm control panel via alarm output modules?
The LMIN-104 is designed to integrate with various lighting control devices, including room controllers and Lighting Control Panels. However, interfacing with a fire alarm control panel via alarm output modules depends on the specific system requirements and wiring configurations. Compatibility and integration may require additional interface devices or relays to ensure proper functionality and compliance with safety standards. For detailed application guidance, we recommend consulting the fire alarm system manufacturer for their requirements. Additionally, speaking with a Legrand Application Engineer may be helpful in determining the best approach for your specific setup.
Date published: 2025-03-27
I have this interface in a patient room, I control the light using my pillow speaker and an extra device. Every time that my second device triggers the interface the light works but the interface blue status light starts resetting. why?
We don't know the details of this setup, but we can tell you that the LMIN-104 is an input device only. It cannot provide feedback to the pillow speaker or any other system other than the local DLM system. We suggest you contact your local Wattstopper representative for a site visit to determine whether this is an issue where we can provide further support or if there is a potential issue with your pillow speaker.
Date published: 2024-01-31
Is this BAA compliant?
Hi Julia,
At present this product is not BAA Complient. In an effort to clearly identify our BAA products the part codes with a -U at the end are BAA compliant.
Date published: 2023-08-09
I need to control an LMCP24 via a theatrical lighting console (ideally, DMX). Is there a way to send DMX control data into an LMPI, so that I can control the 0-10v auditorium house lights from this panel?
The nature of this request is best addressed by an application specialist. Please contact Wattstopper Technical Support @800-879-8585 so that your request can be directed through the proper channels
Date published: 2022-06-20
Bazaarvoice SAP Hybris Integration Version 2.8.1