DLM PLUGLOAD CONTROLLER 20A METERED USA
LMPL-111-20M-U
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
The LMPL-111-20M Plug Load Controller contains a 20 amp relay for on/ off control of connected outlets, and a highefficiency intelligent switching power supply. This plug load controller works as part of the Wattstopper Digital Lighting Management (DLM) system and enables energy-efficient control of plug loads.
BAA
No
- No
- Yes
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Plenum-rated controller with line voltage relay and intelligent switching power supply
- Knockout mounting for easy installation
- Advanced real time metering of voltage and current (+/- 2% accuracy)
- Plug n’ Go™ automatic configuration for quick installation and maximum energy efficiency
- Accepts occupancy sensor signal or schedule events for energy saving control of plug load
- Plugs to other components using Cat 5e cable and RJ45 connectors eliminating wiring errors
Specifications
General Info
Product Line | Wattstopper | ||
Color | White | ||
UPC Number | 754182944217 | ||
Country Of Origin | United States | ||
Product Series | LMPL | ||
Installation Location | Ceiling | ||
Application Sector | Commercial | ||
Standard | UL 88T9, UL 2043, cUL, FCC part 15, PEP, RoHS, BAA, TAA | ||
Warranty Type | 5-Year | ||
Type | Room Controller |
Dimensions
Product Width US | 3.9 in | ||
Product Weight US | 0.6 lb | ||
Product Volume US | 44.6 cu in | ||
Product Depth US | 2.0 in | ||
Product Height US | 4.4 in |
Technical Information
Operating Temperature Min | 32 °F | ||
Output Voltage | 24 VDC | ||
Number of Connections | 2 | ||
Operating Temperature Max | 131 °F | ||
Topology | Free Topology | ||
Number of Relays | 1 | ||
Connector Type | RJ45 | ||
Input Voltage | 120 V | ||
Line Frequency | 50 Hz, 60 Hz | ||
Indoor/Outdoor | Indoor | ||
Mounting Type | 1/2 in Knockout, 4 in Deep J-Box | ||
Current Draw | 20 A | ||
Operating Temperature | 0°-55°C, 32°-131°F | ||
Operating Humidity | 5-95% RH (Non-Condensing) | ||
Storage Temperature | 23° - 176° F |
Resources
Installation Instructions
CAD Drawings
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
If black w/ white stripe and regular black are tied together, will this still work? In a case where the avaliable box in a room doesn't have the receptacle "home run", just the constant hot and switch leg,
The black/white wire allows the device to monitor power use of unswitched receptacles (red is switched, black/white is unswitched, but both are metered). Connections to the LMPL should only be made as shown in the installation instructions (ie black/white is an output to receptacles, not an input from line). Receptacles can be ran directly from line feed hot/neutral without connecting to LMPL in the requested manner. This will not allow the LMPL to meter them however, as they would no longer be connected through it.
Date published: 2024-05-14
What os the purpose of wiring unswitched receptacle to the Black with white stripe?
Hi Jim,
The black with white stripe wire is the load wire for the non-switched receptacles. The red wire is the load for the switched receptacle.
Date published: 2023-06-29
Can a switch control the LMPL-111 instead of an occupancy sensor or scheduled event?
Hi JM
Yes, the loads can be assigned to DLM switches.
Date published: 2023-03-17
Bazaarvoice SAP Hybris Integration Version 2.8.1