Discontinued - PIR Wall Switch Occupancy Sensor, 120/277V, Red
PW-100-R
Wattstopper
Bazaarvoice SAP Hybris Integration Version 2.8.1
Replaced by PW-301-R
The PW-100 passive infrared (PIR) wall switch sensor can turn lights OFF and ON based on occupancy. It is characterized by high sensitivity to small and large movements, appealing aesthetics, and a variety of features.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- High sensitivity and dense coverage for exceptional performance
- No neutral wire required
- Color-matched lens and low profile for appealing design
- Selectable operation, walk-through, test and presentation modes for increased energy savings and convenience
- Defaults to Manual-ON operation for maximum energy savings.
- Defaults to Manual-ON operation for maximum energy savings.
Specifications
General Info
Color | Red | ||
Application Sector | Commercial | ||
Product Line | Wattstopper | ||
Country Of Origin | China | ||
Replaced by Part NumberĀ | PW-301-R | ||
Features | IR (Infrared), Motion Sensor | ||
Switch Type | Motion Sensor | ||
Warranty Type | 5-Year | ||
UPC Number | 754182934409 |
Dimensions
Product Depth US | 1.8 in | ||
Product Height US | 4.1 in | ||
Product Volume US | 36.0 cu in | ||
Product Width US | 1.8 in | ||
Product Weight US | 0.25 lb |
Additional Information
Product Environmental Profile | Yes |
Technical Information
Amperage | 4.3 A | ||
Requires Neutral Wire | No | ||
Connection Type | Wired | ||
Indicator | LED Light | ||
Number of Buttons | 1 | ||
Response Frequency | 50/60 Hz | ||
Sensor Type | Occupancy | ||
Sensor Technology | Passive Infrared (PIR) | ||
Wattage | 1200 W |
Resources
CAD Drawings
57-304-1 - Typical Wiring PW-100 and PW-100-347
dwg
57-304-1 - Typical Wiring PW-100 and PW-100-347
pdf
57-304-1 - Typical Wiring PW-100 and PW-100-347
dxf
57-304-1 - Typical Wiring PW-100 and PW-100-347
png
PW-100cp - PW-100 Coverage Pattern
dwg
PW-100cp - PW-100 Coverage Pattern
dxf
PW-100cp - PW-100 Coverage Pattern
png
View More
Specifications
Product Environmental Profile
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
exactly where do you put the masking on the sensor part?
Masking tape placement is subjective to each installation but generally you would place the tape on the corner or edge of the sensor facing the area you don't want to detect motion.
Date published: 2024-10-18
Bazaarvoice SAP Hybris Integration Version 2.8.1