The PW-301 passive infrared (PIR) wall switch sensor can turn lights OFF and ON based on occupancy. It is characterized by high sensitivity to small and large movements, appealing aesthetics, and a variety of features.
Color Ivory
BAA Yes
Voltage 120/277 VAC
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • High sensitivity and dense coverage for exceptional performance
  • Defaults to Manual-ON operation for maximum energy savings
  • Color-matched lens and low profile for appealing design
  • Optional neutral connection with break off tab to expose neutral terminals
  • 120/240/277 VAC and 347 VAC models
  • Allows multi-way control from one of up to four control locations

Specifications

General Info
Product Line Wattstopper
Color Ivory
UPC Number 754182938513
Country Of Origin United States
Product Series PW-300
Features Adjustable Time Delay, Indicator Lights, Light Level Sensor, Sensitivity Adjustment, Vandal Resistant Lens
Switch Type Motion Sensor
Installation Location Wall
Included Sensor Mask
Application Sector Commercial
Standard UL, cUL, BAA, TAA
Warranty Type 5-Year
Type Sensor, Switch
Dimensions
Product Width US 1.75 in
Product Weight US 0.3 lb
Product Volume US 35.1 cu in
Product Depth US 1.81 in
Product Height US 4.1 in
Technical Information
Has Battery No
Number of Connections 5
Sensor Coverage Pattern 180 deg
Sensor Type Occupancy
Sensor Mounting Height 4 ft
Number of Buttons 1
Amperage 4.3 A
Number of Rockers 0
Sensor Technology Passive Infrared (PIR)
Input Voltage 120/240/277 VAC
Requires Neutral Wire No
Line Frequency 50 Hz, 60 Hz
Wattage 1200 W
Mounting Type In-Wall
On Function Selectable Auto/Manual
Sensing Range Major motion 35 x 30 ft,Minor motion 20 x 15 ft
Wire Connection Type Flying Leads
Load 1000W

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Do you guys make a bottom cover for this? cause i have one on a job with a broken cover and the switch still works i would hate to buy a whole new switch just for that cover.

Asked by: Sam
Unfortunately, Wattstopper does not sell replacement button covers.
Answered by: Justin
Date published: 2024-11-26

Can the PW-301-1 be used with ceiling mounted OC sensors like the CI-355-1?

Asked by: Joel
Greetings Joel, Both devices are recommended to have constant power, and typically installed as standalone devices. We suggest DLM if we are needing additional coverage in the space.
Answered by: Justin
Date published: 2024-11-05

Wiring diagram for 3 sensors.

Asked by: Jared Cattooo
You can include up to 4 PW-301's in a multi-way configuration. Simply add switches to the wiring diagram shown in the installation instructions which can be found at the following URL: https://www.legrand.us/lighting-controls-and-systems/occupancy-and-vacancy-sensors/wall-switch-occupancy-and-vacancy-sensors/pir-wall-switch-occupancy-sensor-white/p/pw-301-w The additional switches would be added in a similar fashion to the leftmost switcch in the wiring diagram, with the load wires capped off on all but one of the switches, which is connected to the load.
Answered by: Tier 1 Tech Support
Date published: 2024-03-28

can a PW-301 replace a PW-101.

Asked by: Anonymous
Yes, the PW-301 is the direct replacement for the PW-101.
Answered by: Justin
Date published: 2024-01-31

Cam switches be wire in parallel with other oc sensors and power packs

Asked by: Jamie
Jamie, The Wattstopper Low voltage versions can, i.e. DW-100-24 sensor switch can be wired in parallel to a DT-300 ceiling sensor.
Answered by: Justin
Date published: 2024-01-25

Is a PW-301 suitable for a 3 way application?

Asked by: Anonymous
Hello, The PW301 supports Multi-Way capability. Sensors can easily be wired together for convenient control of a common load. When wiring this way, only use 300 series sensors. Multi-Way in 300 series is not compatible with prior sensor models. Best Regards, Technical Support
Answered by: Justin
Date published: 2023-05-02

How to set tip switch to 30min. and turn lights on and off when you walk in to the room?

Asked by: Sione Ngaluafe
Hi Sione, Please see chart below for dipswitch settings for your sensor. 30 mins = 1/2/3 on/on/off and 8/9 both off to enable auto on feature.
Answered by: Tier 1 Tech Support
Date published: 2024-08-09

Can this PIR switch be used with LED fixtures?

Asked by: Bryan10
Hello Bryan10, PW301R will support LED fixtures. Best Regards, Technical Support
Answered by: Justin
Date published: 2023-02-16
  • y_2024, m_12, d_25, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_12
  • loc_en_US, sid_PW-301-I-U, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 23ms
  • QUESTIONS, PRODUCT