Wiremold 500/700 Series Small Raceway, White
700WH
Wiremold
Bazaarvoice SAP Hybris Integration Version 2.8.1
Wiremold 700 Series is ideal for surface mounting small amounts of electrical wiring or communication cables. This rugged raceway offers a low profile appearance which blend with any decor. Available in our exclusive ScuffCoat finish.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Features
- Rugged steel raceway. Provides superior strength for any dry location installation.
- Low-profile, unobtrusive appearance. Blends with any decor or setting. Excellent for low-voltage wiring.
- Base and cover are a preassembled one-piece unit. Facilitates easy installation and provides excellent security. ScuffCoat finish. Tough, durable, scratch-resistant finish which can be overpainted with latex paint.
- Surface mounting. Eliminates disturbing the building structure or wall finish to make renovations easy.
- Full line of fittings. Provides unlimited wiring solutions and interconnection between raceway systems.
- More choice of colors. 700 Series Raceway and Fittings are available in ivory and white.
- Fittings have removable covers. Allows easy access to wiring for changes and additions. Raceway cutters with replaceable blades. Cuts raceway cleanly, reduces labor, and installation time.
- Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use.
- UL5 and ADA compliant. Raceway and fittings meet UL5 specifications and can be installed in conformance with ADA requirements.
Specifications
General Info
Product Line | Wiremold | ||
Color | White | ||
UPC Number | 786776562736 | ||
Country Of Origin | United States | ||
Application Sector | Commercial | ||
Standard | cULus Listed Surface Metal Raceway: File E4376: Guide RJBT/RJBT7 | ||
Type | Raceway |
Dimensions
Product Width US | 120.0 in | ||
Product Weight US | 31.26 lb | ||
Product Volume US | 56.7 cu in | ||
Product Depth US | 0.63 in | ||
Product Height US | 0.75 in |
Additional Information
RoHS Conformant | Yes | This product meets the material restrictions of Article 4 of the RoHS Directive (2011/65/EU), including Commission Delegated Directive 2015/863. | |
Product Environmental Profile | Yes |
Listing Agencies / 3rd Party Agencies
cULus ListingNumber | E4376 | ||
cULus Listed | Yes |
Buy American Act Compliance
NAFTA | Yes |
Technical Information
Voltage | 600.0 V |
Resources
Supporting Document
Installation Instructions
2-Gang Device Box - G2048-2
pdf
500 & 700 Series Raceway Corner Fittings
pdf
500 & 700 Series Small Raceway - V500, V700
pdf
500 & 700 Series Small Raceway 1-Gang Device Box - V5747
pdf
500 & 700 Series Small Raceway 2-Gang Deep Switch and Receptacle Box - V5744S-2
pdf
500 & 700 Series Small Raceway 2-Gang Extra Deep Box - V5744-2
pdf
500 & 700 Series Small Raceway 2-Gang Switch & Receptacle Box - V5748-2
pdf
500 & 700 Series Small Raceway 2A Multimedia Surface Mount Boxes
pdf
500 & 700 Series Small Raceway 3-Gang Flush Extension Adapter - V5751-3
pdf
500 & 700 Series Small Raceway 3-Gang Shallow Switch & Receptacle Box - V5748-3
pdf
500 & 700 Series Small Raceway 5700 1/2" EMT Connector - 5791
pdf
500 & 700 Series Small Raceway Adapters - V5719, V5786
pdf
500 & 700 Series Small Raceway Bender Operation - 600B
pdf
500 & 700 Series Small Raceway Blank Extension Box - V5760
pdf
500 & 700 Series Small Raceway Conduit Adapter Fittings
pdf
500 & 700 Series Small Raceway Connecting 2-Gang Device Box Base Plate to Raceway
pdf
500 & 700 Series Small Raceway Connector Fittings
pdf
500 & 700 Series Small Raceway Connectors - 5785, 5790B
pdf
500 & 700 Series Small Raceway Corner Fittings
pdf
500 & 700 Series Small Raceway Deep Switch & Receptacle Box - V5744S
pdf
500 & 700 Series Small Raceway Device Box
pdf
500 & 700 Series Small Raceway Device Box - B1, BWH1
pdf
500 & 700 Series Small Raceway Device Box - B5
pdf
500 & 700 Series Small Raceway Device Box - G2048
pdf
500 & 700 Series Small Raceway Device Box - V2048
pdf
500 & 700 Series Small Raceway Device Box - V5741
pdf
500 & 700 Series Small Raceway Device Box - V5748
pdf
500 & 700 Series Small Raceway Device Box Brackets
pdf
500 & 700 Series Small Raceway Device Boxes
pdf
500 & 700 Series Small Raceway Device Boxes - B1, BWH1
pdf
500 & 700 Series Small Raceway Extension Adapter - 5751AWH
pdf
500 & 700 Series Small Raceway Extension Adapter - V5751A
pdf
500 & 700 Series Small Raceway Extension Box - V5737A
pdf
500 & 700 Series Small Raceway Extension Box - V5739A
pdf
500 & 700 Series Small Raceway Extra Deep Switch and Receptacle Box - V5744
pdf
500 & 700 Series Small Raceway Fan Box - V5738AF
pdf
500 & 700 Series Small Raceway Fittings - 5783, 5784, 5785 & 5790B
pdf
500 & 700 Series Small Raceway Fittings - 5785, 5709GC, 5790B
pdf
500 & 700 Series Small Raceway Fittings - 5790GC, 5709, V5700F
pdf
500 & 700 Series Small Raceway Fixture Box - V5738
pdf
500 & 700 Series Small Raceway Fixture Box - V5738A
pdf
500 & 700 Series Small Raceway Fixture Box Base - V5739
pdf
500 & 700 Series Small Raceway Flexible Section - V5700F
pdf
500 & 700 Series Small Raceway Flush Type 2-Gang Extension Adapter - V5751-2
pdf
500 & 700 Series Small Raceway Flush-Type Extension Adapter - V5751
pdf
500 & 700 Series Small Raceway Internal Pull Elbow & Flexible Section - V5717A, V5700F
pdf
500 & 700 Series Small Raceway Mounting, Seam Clips & Trim
pdf
500 & 700 Series Small Raceway Multi-Gang Box
pdf
500 & 700 Series Small Raceway Shallow Switch & Receptacle 2-Gang Box - V5747-2
pdf
500 & 700 Series Small Raceway Switch & Receptacle 2-Gang Device Box - V2048-2
pdf
500 & 700 Series Small Raceway Transition Fittings
pdf
500 & 700 Series Small Raceway Utility Box - V57242
pdf
500 & 700 Series Small Raceway Utility Box - V5734A
pdf
500 & 700 Small Raceway Combination Switch & Receptacle Box - V5745
pdf
500 & 700 Small Raceway Laser Level & Cutting Guide
pdf
500 & 700 Small Raceway Shallow Switch & Receptacle Box - V5748S
pdf
Metal Raceway Device Boxes
pdf
Round Blank Extension Box - V5734
pdf
View More
Product Environmental Profile
Instruction Sheet
500 & 700 Series Small Raceway - 5736, 5733, 5719, 5786
pdf
500 & 700 Series Small Raceway Distribution Box - V5735
pdf
500 & 700 Series Small Raceway Duplex Grounding Receptacle Device Box - V57243G
pdf
500 &700 Series Small Raceway Shallow Device Box - V5747-3
pdf
Single-Pole Switch & Box - V57240
pdf
View More
Brochure
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
for 40% fill, can I run (2) #8 thhn and (1) #10 thhn
Hello Charlie,
Thank you for your inquiry. Our UL listing report allows for up to 3 #8-gauge conductors when utilizing THHN/THWN wire. Therefore, is acceptable to utilize (2) #8 and (1) # 10 conductor in the 700 series profile.
Date published: 2022-07-13
Are there 45 degree fittings available?
Hi Ryan -
The 45 degree flat elbow for the 700WH is part number 712WH. We do not have an inside or outside 45 degree fitting.
Thanks,
Date published: 2022-06-09
Is Wiremold 500 series raceway an adequate equipment ground conductor?
Hello,
Yes, Legrand Wiremold 500 and 700 Series Surface Raceway and Fittings can be used to provide a reliable ground path when installed in compliance with our Installation Instructions. The system only requires one direct connection to the equipment ground where the premise wiring enters the raceway system to comply with Article 386.60 on the NEC.
Thank you
Date published: 2022-05-13
Is there an end cap for the 700 series raceway?
Hello,
The 700 series is intended to end at a wall or into a device box. The smallest fitting that can be used closest to an end cap is the V57242 small utility box. The V57242 measures 4 1/8" long x 2" wide x 1 3/8" deep. Here is a link for reference:
https://www.legrand.us/wire-and-cable-management/raceway-and-cord-covers/steel/500-700-utility-box-fitting/p/v57242?text=v57242
Thank you,
Date published: 2022-04-21
Can this raceway be surface mounted to the floor?
Hello Jimbob47,
The installation of our raceway should be in accordance with our installation instructions to comply with our UL listing. Our listing and instructions do not specifically indicate where the raceway can or cannot be installed.
The local Authority Having Jurisdiction (AHJ) should be consulted for approval of any installation not specifically covered in our installation instructions.
Thank you!
Date published: 2023-07-08
Can this raceway be attached with screws? Is it two pieces?
Hello Greg,
Two options exist for mounting the V500, V700 or 700WH raceways to the surface. The V5703 (ivory) or 5703WH (white) is a support clip that fastens to the wall first. After the proper number of support clips have been fastened to the surface, the appropriate raceway can then be snapped into the support clips. The recommended spacing for the support clips is every 30” intervals.
The other option is the V504 mounting strap which can be used with V500 raceway, V704 for V700 raceway, or 704WH for 700WH raceway. This strap goes over the front of the raceway and fastens to the surface using both mounting holes in the strap, or can be broken off at the score to convert the strap to a one-hole strap. Similar to the supporting clip, the mounting straps should be spaced at every 30” intervals along the surface.
Date published: 2023-03-01
I bought the bwh1 wiremold. For my application, I will be making a number of cuts and want to purchase just the bushings. Can I buy packs of them--not the full accessory pack, which I do not need?
Hi Ryan,
All parts are available individually through commercial distribution. The bushing is par number 702. The BWH1 is the retail version of our 700WH series. This link will provide all available parts for that system. These can be ordered through our local electrical distributors. If you need assistance with where to buy please contact our sales team for assistance. The phone number is 1-844-957-3783, or you can email directly to customer.support-wm@legrand.us. Just send an email with your zip code and we'll be able to provide a list of local distributors in your area.
Here is the link for the full spec sheet:
https://legrand.webdamdb.com/directdownload.php?ti=55650236&tok=oljzNIHHcKRk8t4xA72KtwRR
Date published: 2022-01-24
Hello, I would like to run a 3' long section of Wiremold 500/700 Series Small Raceway up a wall and then route the electrical cable 90 degrees into the wall to a receptible on the other side of the wall. Do you have a cover for this type of transition?
Hello Daniel,
If I understand the application correctly I believe the V5784 elbow conduit connector would help you achieve this transition and device termination on the other side of the wall using one of our device boxes from the 500/700 series.
1/2" conduit could be connected to the 1/2" knockout on the base plate of the device box and the other end connected to the V5784 fitting.
If you'd like to discuss this in further detail please reach out to us direct. We can be reached at 1-844-957-3783. From the main menu choose option 2 for Wiremold followed by option 2 for Technical Support.
Thank you for your interest in Legrand products!
Date published: 2021-11-29
I need installation instructions for the BWH1 Raceway that I bought at Lowe's.
Please follow the link below to download a PDF copy of the installations instructions sheet for the V500/V700 raceways. The BWH1 is the same raceway as the V700 except it's white.
https://legrand.webdamdb.com/directdownload.php?ti=55652801&tok=YVseksUMGetzHLmj9wv1pQRR
Also, the link below will take to a page on our web site where you can download additional installation instructions sheets for the various fittings in that series.
https://www.legrand.us/wire-and-cable-management/raceway-and-cord-covers/steel/wiremold-500-700-series-small-raceway-white/p/700wh?text=700wh
Date published: 2021-10-29
Bazaarvoice SAP Hybris Integration Version 2.8.1