15A/125A NAFTA-Compliant Trademaster® Tamper-Resistant Duplex Receptacle
Color Ivory
  • Send
  • Save as PDF
  • Add to favorites Remove from favorites

Features

  • Quality Materials, durability, and time-tested design

Specifications

General Info
Product Line Pass & Seymour
Color Ivory
UPC Number 785007007893
Country Of Origin Mexico
Application Sector Residential/Commercial
Standard UL 498
Dimensions
Product Width US 1.32 in
Product Depth US 1.0 in
Product Height US 4.2 in
Additional Information
Product Environmental Profile Yes
Listing Agencies / 3rd Party Agencies
cULus Listed  Yes
Technical Information
Is Tamper-Resistant Yes
Phase Three
Number of Wires 3
Amperage 15 A
Number of Poles Double Pole
Wire Size 12 AWG

Reviews

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Questions & Answers

Is this device rated for 20amp feed- through?

Asked by: Rick
Yes, the P&S Legrand 15A receptacles are designed with a 20A feed through capability. They can be installed on a 20A branch-circuit so long as they are not the only device on that circuit. NEC 2008 210.21(B) (3)
Answered by: Legrand Technical Support
Date published: 2020-06-01

Can this rec have two separate circuits on it?

Asked by: Jeremy
Yes, it has split circuit tabs in between the terminals that can be removed.
Answered by: Legrand Technical Support
Date published: 2020-02-05

installed a 3232tr-bkcc14 outlet, have power to the unit, and leaving the unit, power on the lug, but, will not energize any devices.

Asked by: Bryan
Thank you for your question regarding Legrand receptacle 3232TRNABKCC14. I would double check your wiring and if everything is correct. It is difficult to trouble shoot this without more details. I would suggest calling and talking to Technical Support to better determine what the issue is. They can be reached at: Pass & Seymour Legrand products 1.800.223-4162 opt 3 Mon - Fri: 8am - 8pm EST (excluding holidays)
Answered by: Legrand Technical Support
Date published: 2018-04-12
  • y_2024, m_11, d_23, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_US, sid_3232TRNAI, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_legrand
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 26ms
  • QUESTIONS, PRODUCT