LS Series CFL/LED/Incandescent Single Pole/3-Way Slide Dimmer with Single Pole/3-Way, 3-Speed De-Hummer Fan Control, Preset, Light Almond
LSCLDC163PLACCV4
Pass and Seymour
Bazaarvoice SAP Hybris Integration Version 2.8.1
$40.94 USD
The industry's first CFL/LED dimmer with fan speed control works with select dimmable CFL/LED or incandescent lighting loads and features a sleek, sculpted ergonomic design for smooth, easy operation and precise control.
Out of Stock on Legrand.us
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Pass & Seymour | ||
Color | Light Almond | ||
Finish | Matte | ||
UPC Number | 785007040449 | ||
Country Of Origin | China | ||
Features | Combination, Fan Control, Locator Light | ||
Switch Type | Push, Slider | ||
Number of Switches | 2 | ||
Application Sector | Residential | ||
Warranty Type | Limited Lifetime Warranty |
Dimensions
Product Width US | 2.5 in | ||
Product Depth US | 1.28 in | ||
Product Height US | 4.19 in |
Technical Information
Amperage | 1.6 A | ||
Bulb Compatibility | CFL, Incandescent, LED | ||
Number of Poles | 3-Way, Single Pole | ||
Wire Size | #14 - #10 AWG | ||
Wattage | 300 W | ||
Mounting Type | Box |
Resources
Cutsheet
Supporting Document
Reviews
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Hello,I was recommended this product.For the fan I don't need a dimmer switch just power on and off, the Fan has its own remote control.I do need to be able to dimmer another ceiling lamp.Do you have a led/cfl one dimmer and on/off and one on/off?
Thank you for your inquiry. Unfortunately, we do not offer a combination fan speed controller & on/off switch.
Date published: 2024-09-11
Do you have a schematic diagram showing power through one three way switch(with red common wire) to this LSCLDC163P switch where I can then control the overhead light and fan separately?
Thank you for your inquiry. We require additional information to assist you further with your request. Please contact Legrand Pass & Seymour Technical Support at (800) 223-4185 between 8:00 a.m. and 6:00 p.m. EST or via email at Tech.Support@legrand.us.
Date published: 2024-06-25
Why are the light modules TM8LMCC8 discontinued
The decision to discontinue TM8LMCC8 was not taken lightly. After careful consideration, we have determined that the demand for this product has significantly decreased, and it no longer aligns with our current market strategy. Additionally, we are focusing our resources on developing new, innovative products that we believe will better serve your needs and expectations.
Date published: 2024-08-25
Can this controller be used with a fan that also have a remote?
Hello Paul,
Please give Technical Support a call at your earliest convenience to further discuss you wiring configuration.
legrand Contact information:
Phone #: 844-957-3783 - Option 1, followed by option 2 for Technical Support.
Monday - Friday | 8:00am - 6:00pm Eastern Standard Time (excluding holidays)
Best Regards,
Technical Support
Date published: 2024-04-15
I purchased a LSCLDC163PLA light and fan switch. It can be wired as a single pole or 3-way switch. The schematic shows depicts 3 switches, which is a 4-way circuit. Do you have a 3-way schematic (2 switches) for wiring this switch?
I just wired this up, it works great, even added a four way switch.
One thing that is confusing; the 3 way switch on the right in the diagram above, should that be labeled 3 way switch for fan?
Date published: 2024-05-31
I have this switch installed for my ceiling fan and the high speed setting is WAY to fast. Is there any adjustments or things I can add to slow down the highest speed?
Unfortunately, nothing can be done as the capacitors are fixed values within the dehummer control. Please make sure you have the setting on the fan set to "high" before using the dehummer. You can contact us directly if you still need assistance:
Pass & Seymour products
1.844.957-3783
Mon - Fri: 8am - 6pm EST
(excluding holidays)
Email Us - tech.support@legrand.us
Date published: 2024-09-25
Can this be used on a 3 way, fan/light plus recessed lights on the same switch?
If you have the dimmer controlling different types of light loads(CFL/LED's...etc), you may not get the exact same response from them when trying to control the light level.
Date published: 2024-10-06
Does Legrand provide a Dual Dimmer for 2 LEDs in one control? Can I use the LSCLDC163PW to control 2 LEDs instead of one LED and a fan?
We do not have a dual LED dimmer available and the fan control is not designed to handle a LED load as a dimmer.
Date published: 2023-11-03
Bazaarvoice SAP Hybris Integration Version 2.8.1