Discontinued - adorne® Outlet Module 15A, Titanium
APTR15TM4
adorne Collection
adorne Outlet Module 15A is rated
out of
5 by
2.
Bazaarvoice SAP Hybris Integration Version 2.8.1
Ideal for any kitchen where multiple countertop appliances will be plugged in at once. Use this under-cabinet outlet module with two standard outlets to provide convenient power and keep multiple appliances ready, without the clutter. This module can be easily added or removed from the Modular Track by using the module tool included in your purchase. Note: This item is included with the purchase of the Modular Track. Purchase additional outlet modules to further customize your Under-Cabinet Lighting and Power System.
- Send
- Save as PDF
-
Added to Favorites Go to favoritesRemove from favorites?Something went wrong. Please try again later.
Specifications
General Info
Product Line | Pass & Seymour | ||
Color | Titanium | ||
Finish | Satin | ||
UPC Number | 786776178135 | ||
Country Of Origin | China | ||
Receptacle Type | Double | ||
Number of Receptacles | 2 | ||
Application Sector | Residential | ||
Type | Outlet |
Technical Information
Is Tamper-Resistant | No | ||
Connection | adorne under-cabinet track mounted | ||
Amperage | 15 A | ||
Is Weather Resistant | No | ||
Indoor/Outdoor | Indoor | ||
Connection Type | Wired | ||
Environmental Conditions | 95% (relative humidity, non-condensing) |
Resources
Installation Instructions
Brochure
Supporting Document
Customer CAD PDF
Reviews
Rated 5 out of
5
by
kchung02 from
adorne® Outlet Module 15A
We went with the whole Legrand package. Outlets, lights, dimmers. LOVE!!!
Date published: 2022-05-09
Bazaarvoice SAP Hybris Integration Version 2.8.1
Questions & Answers
Hello, we recently bought a house with some of these outlets and lights under the cabinet in the kitchen. it doesn't appear they have GCFI outlets in any of the strings. other than the obvious button on the outlet, is there another possible location it
Thank you for your inquiry. The adorne undercabinet system supports a GFCI either at the control box location or by using a GFCI breaker at your electrical panel.
Example:
Part #: APCB6W2
If you have any other questions or comments, please get in touch with us at (800) 223-4185 8:00 a.m. – 6:00 p.m. EST or by email at Tech.Support@legrand.us.
Date published: 2024-06-26
Are these under counter light + receptacle strips currently available?
Thank you for your inquiry. The part number APTR15TM4 has been discontinued.
Date published: 2024-05-15
Do these outlet modules wear out or short out? We have a strip with 2 outlet modules that stopped working. We reset the breaker in our main breaker box but that didn’t solve the problem. Any suggestions?
Hello, Please call in to Technical Support so we can troubleshoot with you. You can reach us at 844-957-3783.
Date published: 2023-08-29
My kitchen has two 20amp circuits. I understand I can put in GFCI breaker at the panel. All of the outlets on the circuit are rated 15amp receptacles, however it is 12 gauge wire feeding them. Is it within code to use 14 wire to feed receptacles?
The Under Cabinet Track receptacles get their power from either a Control Box or Direct Wire Connector and they will accept both #12 and #14 AWG wire.
Date published: 2021-04-26
Are there 20 amp receptacle that go into the the strip. Do you sell a gfci module or do we need to intall in the panel?
The under cabinet receptacles are 15A that are installed on a 20A circuit. The GFCI protection can either come from a Control Box with GFCI or at the breaker panel.
Date published: 2020-06-03
how do the adorne collection undercabinet receptacles meet the 20 amp circuit requirement for kitchen applications or do you offer a 20 amp module??
The receptacle circuit must be 20 amps(per code), use #12 wire, and be GFCI protected.
The separate lighting and accessory circuits must be at least 15 amps each, and can use
#14 wire.
Date published: 2020-10-29
do they meet 210.8 and 210.52 requirements?
They meet 210.52 for all 125-volt, 15- and 20-amp receptacles shall be
listed tamper-resistant receptacles.
These do not meet 210.8 on their own because they do not provide GFCI protection. If You have the circuit protected with a GFCI it will.
Date published: 2018-09-05
Bazaarvoice SAP Hybris Integration Version 2.8.1
You may also like...
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
ALLNLEDTM4 | adorne Collection
adorne LED UNDER-CABINET LINEAR LIGHT is perfect for anywhere a brighter countertop work space is required, or where counter real estate is limited.
$70.40
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
APCB4TM1 | adorne Collection
Control box for use with adorne Under-Cabinet solutions.
$42.80
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
APUSB3TM4 | adorne Collection
Provides two USB charging ports for devices such as mobile phones and tablets by simply snapping into any module opening on the track.
$65.54
Added to Favorites
Go to favorites
Remove from favorites?
Something went wrong. Please try again later.
AAPCTM4 | adorne Collection
Cradle attaches anywhere along the Modular Track to hold a mobile phone.
$25.54